Product Details:

Place of Origin: Jiangsu, China (Mainland)
Brand Name: chieful
Model Number: CSM2000LTE

Payment & Shipping Terms:

Minimum Order Quantity: 1 Piece
Price: Negotiable
Contact Now
Detailed Product Description
Usage: Magnetic Sensor Theory: Hall Sensor
Output: Analog Sensor Color: Black
Diameter: 72mm Weight: 1280g
Selling Units: Single Item Single Package Size : 26X19X17 Cm
Single Gross Weight: 1.28 Kg Package Type: Packing In Bubble And Carton

DC AC Pulsed Closed Loop Hall Current Sensor , Hall Effect Current Transducer

 

Production Description:

 

Application of the closed-loop hall effect current sensor,Current are highly insulated between the primary and secondary loop.It can be used for measurement of DC,AC pulse and kinds of irregular voltage waveform.

 

Main features:
 

1. High Accuracy Close loop current transducer

2. Hall effect principle, Measure AC, DC, Pulse current

3. They are especially useful for Electric cars and Battery Monitor Systems (BMS).

 

Closed loop current transducer CSM2000LTE

 

Electrical characteristics
  Type CSM2000LTE  
IPN Primary nominal input current 2000 A
IP Measuring range of primary current 0~±3000 A
KN Conversion ratio 1:5000  
RM Measuring resistance (VC=±15V/ IPN) 0~8 Ω
  (VC=±15V/ IP) 0~5 Ω
  (VC=±18V/ IPN) 5~29 Ω
  (VC=±18V/ IP) 5~11 Ω
VC Supply voltage ±12~±18(±5%) V
IC Current consumption VC=±15V 20+Is mA
VD Insulation voltage AC/50Hz/1min 6 kV
εL Linearity <0.1 %FS
X Accuracy TA=25℃ <±0.7 %
I0 Zero offset current TA=25℃ <±0.25 mA
IOM Residual current IP→0 <±0.2 mA
IOT Thermal drift of I0 IP=0 TA=-25~+85 <±0.65 mA
TR Response time <1 μs
di/dt di/dt accurately followed >100 A/μs
f Frequency bandwidth(-3dB) DC~100 kHz
TA Ambient operating temperature -25~+85
TS Ambient storage temperature -40~+100
RS Secondary coil resistance TA=25℃ 22 Ω
  Standard Q/320115QHKJ01-2010

 

DC AC Pulsed Closed Loop Hall Current Sensor , Hall Effect Current Transducer

About us

DC AC Pulsed Closed Loop Hall Current Sensor , Hall Effect Current Transducer

CHIEFUL offers a wide range of current and voltage transducers in the portfolio. And our transducer can be designed according to the specific demands.The company explore foreign markets actively, our products have been sold to the United Kingdom, Germany, Denmark, France, Italy, Sweden,Turkey, Israel, South Korea, India etc.

DC AC Pulsed Closed Loop Hall Current Sensor , Hall Effect Current TransducerDC AC Pulsed Closed Loop Hall Current Sensor , Hall Effect Current Transducer 

Exhibition

DC AC Pulsed Closed Loop Hall Current Sensor , Hall Effect Current Transducer 

Logistics packaging

DC AC Pulsed Closed Loop Hall Current Sensor , Hall Effect Current Transducer

DC AC Pulsed Closed Loop Hall Current Sensor , Hall Effect Current Transducer

 

FAQ

 

Q1: Are you a factory?
A:We are a factory setted up more than 17 years and export more than 10years.

Q2: When is the delivery date?
A: 7-10 working days in general.

Q3: Could you send me a quotation?
A: Sure.

Q4: How about the after service?
A: Five years warranty.

Q5: What about the shipping package?
A: Anti-static package and carton.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Contact Details
Nanjing Chieful Science & Technology Co., Ltd.

Contact Person: admin

Send your inquiry directly to us (0 / 3000)