Home ProductsHall Effect Current Transducer

Open Loop Type Hall Effect Current Transducer 500A Input 20mm Diameter

Certification
Good quality Open Loop Current Sensor for sales
Good quality Open Loop Current Sensor for sales
I'm Online Chat Now

Open Loop Type Hall Effect Current Transducer 500A Input 20mm Diameter

China Open Loop Type Hall Effect Current Transducer 500A Input 20mm Diameter supplier
Open Loop Type Hall Effect Current Transducer 500A Input 20mm Diameter supplier Open Loop Type Hall Effect Current Transducer 500A Input 20mm Diameter supplier

Large Image :  Open Loop Type Hall Effect Current Transducer 500A Input 20mm Diameter

Product Details:

Place of Origin: China
Brand Name: chieful
Certification: CE,Rohs,ISO9001
Model Number: CS500E

Payment & Shipping Terms:

Minimum Order Quantity: 1PC
Price: Negotiable
Packaging Details: Carton
Delivery Time: 5 Days
Payment Terms: T/T
Supply Ability: 100000pcs/month
Contact Now
Detailed Product Description
Color: Black Weight: 78g
Type: Open Loop Capacity: 100000/month
Power Supply: +/-15V Linearity: <1%FS

500A , 20mm Diameter Hall Effect Current Transducer 4V output

 
open loop device based on the measuring principle of the hall effect, with a galvanic isolation between primary and secondary circuit. It provides accurate electronic measurement of DC, AC or pulsed currents.
 
 
Hall current sensors are widely applicable for acquisition and feeback control of current signals in the current monitoring,inverter,solar power management,current cabinet,DC motor drive and UPS servo control systems.
 

Electrical characteristics
 TypeCS050ECS100ECS200ECS300ECS400ECS500E 
IPNPrimary nominal input current50100200300400500A
IPMeasuring range of primary current 0~±1000~±2000~±4000~±6000~±8000~±800A
VOUTNominal output voltage 4±1%V
VCSupply voltage±12~±15(±5%)V
ICCurrent consumption VC=±15V <20mA
VDInsulation voltageAC/50Hz/1min 2.5kV
εLLinearity<1%FS
VOOffset voltageTA=25℃ <±25mV
VOMResidual voltage IPN→0 <±20mV
VOTThermal drift of V0IP=0 TA=25~+85℃ <±1mV/℃
TRResponse time≤3μs
fFrequency bandwidth(-3dB)DC~20kHz
TAAmbient operating temperature 25~+85
TSAmbient storage temperature 40~+100
RLLoad resistance ≥10KΩ
 StandardQ/3201CHGL02-2016 

Dimensions of drawing (mm)

Open Loop Type Hall Effect Current Transducer 500A Input 20mm Diameter

Remarks

·Incorrect connection may lead to the damage of the sensor.
·VOUT is positive when the IP flows in the direction of the arrow.